{ "id":6179504160958, "title":"AEMC 603 True RMS Clamp Meter with Temperature, 2000A AC\/3000A DC","handle":"aemc-603-true-rms-clamp-meter-with-temperature-2000a-ac-3000a-dc", "description":"\u003cp\u003e\u003cspan\u003eThe TRMS Clamp-on Meter Model 603 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in all electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 603 offers several unequaled functions including: \u003c\/span\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003cspan\u003e, Adapter function, Delta relative function, temperature measurement, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC and DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 2000AAC and 3000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures temperature in °F or °C using a K-type Thermocouple\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eAdapter function to accept inputs from sensors and transducers with a millivolt output with user programmable scaling\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 2.36\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2000Arms AC, 3000ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts, 5% ± 5cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10 to 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTemperature K Thermocouple:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-76.0 to 2192°F (-60 to 1200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAdapter Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e11.65 x 4.37 x 1.61\" (296 x 111 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.4 lbs (640g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2.36\" (60mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20° to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40° to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-On Meter with Temperature\u003c\/li\u003e\n\u003cli\u003eSilicone Color Coded Insulated Test Leads\u003c\/li\u003e\n\u003cli\u003eTest Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eK-Thermocouple with 4mm Integrated Adapter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x AA Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 603 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 603 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2021-01-18T10:53:06", "created_at":"2021-01-18T10:53:05", "vendor":"AEMC Instruments", "type":"Clamp Meters", "tags":[], "price":59400, "price_min":59400, "price_max":59400, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[37911341269182], "variants":[{ "id":37911341269182, "product_id":6179504160958, "product_handle":"aemc-603-true-rms-clamp-meter-with-temperature-2000a-ac-3000a-dc", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"AEMC-2139.31", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"AEMC 603 True RMS Clamp Meter with Temperature, 2000A AC\/3000A DC - Default Title", "options":["Default Title"], "price":59400, "weight":4082, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"685338110272"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC603Pic1.png?v=1610992388"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC603Pic1.png?v=1610992388", "options":["Title"], "url":"\/products\/aemc-603-true-rms-clamp-meter-with-temperature-2000a-ac-3000a-dc"}

AEMC 603 True RMS Clamp Meter with Temperature, 2000A AC/3000A DC

Product Description

The TRMS Clamp-on Meter Model 603 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in all electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 603 offers several unequaled functions including: True InRush®, Adapter function, Delta relative function, temperature measurement, and more.

Sku: AEMC-2139.31
On Back-Order
$594.00 CAD

  • 1000V CAT IV Rated
  • UL 94 flame retardant self-extinguishing
  • IP54 Rated
  • 10,000-count blue electroluminescent backlit display
  • Measures up to 1000VAC (1400V peak), 1000VDC and AC and DC with resolution to 10mV
  • Measures up to 2000AAC and 3000ADC
  • Measures temperature in °F or °C using a K-type Thermocouple
  • Measures frequency to 20kHz with 0.1Hz resolution
  • Auto selects AC or DC measurement voltage
  • True InRush® current measurement with 1mS capture
  • Delta relative function for tracking deviation from reference values
  • Adapter function to accept inputs from sensors and transducers with a millivolt output with user programmable scaling
  • Jaw opening up to 2.36"
  • Leads are constructed with a flexible silicone material
Voltage Range: 1000Vrms AC/DC Autoranging
Resolution Max: 0.01V
Current Range: 2000Arms AC, 3000ADC
Resolution Max: 0.01A
Accuracy V Typical: 1% ± 3cts
Accuracy A Typical: 1% ± 3cts, 5% ± 5cts
InRush: 10 to 1000A
Continuity: Selectable from 0 to 999.9Ω
Resistance: 100kΩ
Diode Test: 0 to 3.2VDC
Frequency: 20kHz in V, 2kHz in A
Temperature K Thermocouple: -76.0 to 2192°F (-60 to 1200°C)
Adapter Function: Yes
MIN/MAX: Yes
∆REL: Yes
Power Source: 4 x AA, NEDA 15A, IEC LR6
Battery Life: >350 hours
Dimensions: 11.65 x 4.37 x 1.61" (296 x 111 x 41mm)
Weight: 1.4 lbs (640g) with batteries
Jaw Opening: 2.36" (60mm)
Operating Temperature: -4° to +131°F (-20° to +55°C)
Storage Temperature: -40° to +158°F (-40° to +70°C)
Operating Humidity: 90% up to 131°F (55°C)
Pollution Degree: 2
Ingress Protection: IP54
EMC: EN61326-1
Safety Compliance: EN/IEC 61010-1 to 1000V CAT IV
EN/IEC 61010-2-030:2010
EN/IEC 61010-032:2002


  • True RMS Clamp-On Meter with Temperature
  • Silicone Color Coded Insulated Test Leads
  • Test Probes
  • Alligator Clips
  • K-Thermocouple with 4mm Integrated Adapter
  • Soft Carrying Case
  • 4 x AA Batteries