{ "id":6179663610046, "title":"AEMC 405 True RMS Clamp Meter with Phase Rotation, 1000V AC\/DC, 1000A AC\/1500A DC","handle":"aemc-405-true-rms-clamp-meter-with-phase-rotation-1000v-ac-dc-1000a-ac-1500a-dc", "description":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 405 is safety rated at 1000V CAT IV. AC DC clamp meter - it measures AC, DC, and AC+DC volts, amps and power. The Model 405 also measures resistance, frequency, \u003c\/span\u003e\u003ca href=\"http:\/\/aemc.skyworld.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003e\u003cstrong\u003e\u003cspan color=\"#004f92\" style=\"color: #004f92;\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003cspan\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003etemperature, phase rotation, and continuity. It can also perform diode checks. This rugged meter can operate in the most demanding work environments, and its IP54 rating allows it to withstand both dust and water spray.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000AAC and 1500ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eDisplays Power Factor\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement\u003c\/li\u003e\n\u003cli\u003eMeasures AC+DC volts, amps and power\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eMeasures THDr and THDf \u003c\/li\u003e\n\u003cli\u003eDetects and displays phase rotation\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eTracks Min\/Max values\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC\/AC+DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Arms AC, 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10 to 1000AAC, 10 to 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Measurement Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1MW AC, 1.5MW DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTHD:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, %f and %r\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePhase Order:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX\/PEAK-\/PEAK+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10.7 x 3.6 x 1.6\" (272 x 92 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.32 lbs (600g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.9\" (48mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20° to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40° to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"\"\u003e\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Meter\u003c\/li\u003e\n\u003cli\u003e2152.03 Silicone Lead Set, 1000V, CAT IV Rated\u003c\/li\u003e\n\u003cli\u003e2139.72 Soft Carrying Case\u003c\/li\u003e\n\u003cli\u003eSet of 4 AA 1.2V Batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 405 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 405 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2021-01-18T12:22:52", "created_at":"2021-01-18T12:22:51", "vendor":"AEMC Instruments", "type":"Clamp Meters", "tags":[], "price":58100, "price_min":58100, "price_max":58100, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[37911648534718], "variants":[{ "id":37911648534718, "product_id":6179663610046, "product_handle":"aemc-405-true-rms-clamp-meter-with-phase-rotation-1000v-ac-dc-1000a-ac-1500a-dc", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"AEMC-2139.50", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"AEMC 405 True RMS Clamp Meter with Phase Rotation, 1000V AC\/DC, 1000A AC\/1500A DC - Default Title", "options":["Default Title"], "price":58100, "weight":4082, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"685338220414"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC405Pic1.png?v=1610997773"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC405Pic1.png?v=1610997773", "options":["Title"], "url":"\/products\/aemc-405-true-rms-clamp-meter-with-phase-rotation-1000v-ac-dc-1000a-ac-1500a-dc"}
AEMC 405 True RMS Clamp Meter with Phase Rotation, 1000V AC/DC, 1000A AC/1500A DC
Product Description
The True RMS Clamp-On Meter Model 405 is safety rated at 1000V CAT IV. AC DC clamp meter - it measures AC, DC, and AC+DC volts, amps and power. The Model 405 also measures resistance, frequency, True InRush®, temperature, phase rotation, and continuity. It can also perform diode checks. This rugged meter can operate in the most demanding work environments, and its IP54 rating allows it to withstand both dust and water spray.
Sku: AEMC-2139.50
Vendor: AEMC Instruments
On Back-Order
Overview
- 1000V CAT IV Rated
- UL 94 flame retardant self-extinguishing
- IP54 Rated
- 10,000-count blue electroluminescent backlit display
- Measures up to 1000VAC (1400V peak), 1000VDC and AC+DC with resolution to 10mV
- Measures up to 1000AAC and 1500ADC
- Measures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W
- Displays Power Factor
- Measures frequency to 20kHz with 0.1Hz resolution
- Auto selects AC or DC measurement
- Measures AC+DC volts, amps and power
- True InRush® current measurement with 1mS capture
- Measures THDr and THDf
- Detects and displays phase rotation
- Delta relative function for tracking deviation from reference values
- Tracks Min/Max values
- Jaw opening up to 1.89"
- Leads are constructed with a flexible silicone material
Specifications
Voltage Range: | 1000Vrms AC/DC/AC+DC Autoranging |
Resolution Max: | 0.01V |
Current Range: | 1000Arms AC, 1500ADC |
Resolution Max: | 0.01A |
Accuracy V Typical: | 1% ± 3cts |
Accuracy A Typical: | 1% ± 3cts |
InRush: | 10 to 1000AAC, 10 to 1500ADC |
Power Measurement Max: | 1MW AC, 1.5MW DC |
THD: | Yes, %f and %r |
Continuity: | Selectable from 0 to 999.9Ω |
Resistance: | 100kΩ |
Diode Test: | 0 to 3.2VDC |
Frequency: | 20kHz in V, 2kHz in A |
Power Factor: | Yes |
Phase Order: | Yes |
MIN/MAX/PEAK-/PEAK+ | Yes |
∆REL: | Yes |
Power Source: | 4 x AA, NEDA 15A, IEC LR6 |
Battery Life: | >350 hours |
Dimensions: | 10.7 x 3.6 x 1.6" (272 x 92 x 41mm) |
Weight: | 1.32 lbs (600g) with batteries |
Jaw Opening: | 1.9" (48mm) |
Operating Temperature: | -4° to +131°F (-20° to +55°C) |
Storage Temperature: | -40° to +158°F (-40° to +70°C) |
Operating Humidity: | 90% up to 131°F (55°C) |
Pollution Degree: | 2 |
Ingress Protection: | IP54 |
EMC: | EN61326-1 |
Safety Compliance: | EN/IEC 61010-1 to 1000V CAT IV EN/IEC 61010-2-030:2010 EN/IEC 61010-032:2002 |
What's in the Box
- True RMS Clamp-on Meter
- 2152.03 Silicone Lead Set, 1000V, CAT IV Rated
- 2139.72 Soft Carrying Case
- Set of 4 AA 1.2V Batteries
- Manual
Resources
Related Products
AEMC 8345 PowerPad IV Power Quality Analyzer
From $12,873.00 CAD
AEMC ALS-1 Line Splitter
$25.00 CAD
AEMC C.A 773 Voltage Absence Tester
$483.00 CAD
AEMC 8505 Motor/Transformer Tester
$695.25 CAD
AEMC 8510 DTR Digital Transformer Ratiometer, 110/220V
$4,865.00 CAD
AEMC 1954 Thermal Imaging IR Camera, 120 x 160
$3,038.00 CAD